MATT:E CROSS PAVEMENT CHARGING UNIT | IET:01 | TYPE A RCBO | T2 SPD
The matt:e SP-M1b3t-R-SPD provide a simple, dedicated connection point for a single-phase EV charger. Built-in IET:01 M1b3t PEN fault protection enables connection to a PME earthing facility without installing an earth electrode
Tell us about the property, electrical supply, solar PV, mounting position, vehicle, parking layout, required cable reach and your customer’s other requirements.
The matt:e SP-M1b3t-R-SPD provide a simple, dedicated connection point for a single-phase EV charger. Built-in IET:01 M1b3t PEN fault protection enables connection to a PME earthing facility without installing an earth electrode
Product Features
- Application : Single-phase EV connection centre for one 7.4kW EV charge point
- Supply : 230V AC 50Hz; 1P+N+PE
- Rated Load Current : 40A
- Enclosure Rating : IP41 (Indoor)
- Dimensions : 302.2 x 234.84 x 124.42 mm
- Warranty : 1 Year
- Protection Method : IET:01:2024 Category M1b3t
- Voltage Operating Window : 184V to 262.2V
- Trip Current : 21mA
- Start-up Delay : Approx. 20 seconds
- Reset After Fault : Manual Reset
- Impulse Withstand : 10kV
- Ambient Temperature : -25 deg C to +40 deg C
- RCBO : 40A Type C, 30mA Type A
- Short Circuit Capacity : 6kA @ 230V
- SPD Classification : Type 2 / Class II, 1+NPE
- Nominal Discharge Current : 20kA
- Maximum Discharge Current : 40kA
- Protection Level : L-PE 1.5kV, N-PE 1.3kV